smithery/gptomics

bio-flow-cytometry-doublet-detection

Detects and removes doublets/aggregates from flow, spectral, and mass cytometry before clustering or quantification. Covers FSC-A vs FSC-H singlet discrimination (the Area-Height non-proportionality, not a 1D area gate), FSC-W/SSC width gating, CyTOF Gaussian discrimination parameters (Center/Offset/Width/Residual/Event_length) and DNA intercalator gating, and the residual heterotypic conjugates that survive scatter gating and masquerade as double-positive populations. Use when filtering aggreg…

Installation

$ npx skills add smithery/gptomics --skill bio-flow-cytometry-doublet-detection

Summary

  • Detects and removes doublets/aggregates from flow, spectral, and mass cytometry before clustering or quantification.
  • Covers FSC-A vs FSC-H singlet discrimination (the Area-Height non-proportionality, not a 1D area gate), FSC-W/SSC width gating, CyTOF Gaussian discrimination parameters (Center/Offset/Width/Residual/Event_length) and DNA intercalator gating, and the residual heterotypic conjugates that survive scatter gating and masquerade as double-positive populations.
  • Use when filtering aggregates before phenotyping, choosing a doublet method for flow vs CyTOF, or diagnosing a suspicious double-positive cluster.

Also in this package

Other skills from smithery/gptomics · top by installs.

npx skills add smithery/gptomics

Browse all from smithery/gptomics

More details

Agent compatibility

Declared targets from SKILL.md / docs. Unmarked agents are not listed — the skill may still install via the CLI.

Claude Code Not declared
Cursor Not declared
Codex Not declared
GitHub Copilot Not declared
Windsurf Not declared
Gemini CLI Not declared
Cline Not declared
OpenCode Not declared

Package contents

Files included with this skill beyond the listing page.

  • skill md SKILL.md 7,980 B
  • docs SUMMARY.md 255 B

History

  1. First recorded snapshot · 0 installs

SKILL.md

Version Compatibility

Reference examples tested with: flowCore 2.14+, CATALYST 1.26+, ggplot2 3.5+.

Before using code patterns, verify installed versions match. If versions differ:

  • R: packageVersion('<pkg>') then ?function_name to verify parameters

If code throws an error, introspect the installed package and adapt rather than retrying.

Doublet Detection

"Remove doublets from my cytometry data" -> Discriminate single cells from aggregates using pulse geometry (flow) or ion-cloud parameters (CyTOF), before any clustering or quantification.

  • R (flow/spectral): flowCore gate on the FSC-A vs FSC-H diagonal (+ FSC-W/SSC-W)
  • R (mass/CyTOF): gate on DNA intercalator + Gaussian/Event_length parameters

The Single Most Important Modern Insight -- Doublets Are Caught by Area-vs-Height Non-Proportionality, and Scatter Gating Is Necessary but Not Sufficient

A doublet has roughly double the pulse AREA of a singlet but NOT double the Height, and a longer Width/transit time - so singlets fall on a tight FSC-A vs FSC-H diagonal and doublets deflect above it. A 1D area histogram therefore does NOT remove doublets; the discriminating signal is the Area-Height relationship (plus Width). This matters because an unremoved doublet of a CD3+ and a CD19+ cell reads as an artifactual CD3+CD19+ "double-positive," and clustering will faithfully (and wrongly) carve it out as a real population. Crucially, scatter gating is necessary but NOT sufficient: heterotypic conjugates (e.g. a CD3+CD14+ T:monocyte) survive standard FSC-A/H gates and present as genuine double-positives whose lineage-marker levels look COMPARABLE to true single-positives - the tell is an ELEVATED shared marker (e.g. CD45) and a high bright-field aspect ratio, so the definitive resolver is imaging flow cytometry, not a lineage-intensity check (Stadinski 2020 Cytometry A 97:1102). On CyTOF there is no scatter at all - doublets are removed by ion-cloud Gaussian parameters and DNA intercalator content (Bagwell 2020 Cytometry A 97:184).

Method Taxonomy

Method Instrument Principle Caveat
FSC-A vs FSC-H flow/spectral singlets on the A-H diagonal the standard; the discriminator is non-proportionality, not area
FSC-W / SSC-W flow/spectral doublets have longer pulse Width complementary to A-vs-H
DNA intercalator (Ir191/193) CyTOF doublets show ~2N+ DNA also separates cells from beads/debris
Gaussian params + Event_length CyTOF ion-cloud fit residual/length flags fusions catches fusions DNA alone misses (Bagwell 2020)
imaging cytometry imaging flow bright-field aspect ratio the only clean resolver of heterotypic conjugates

Note: cytometry doublet removal is GATING-based. DoubletFinder/Scrublet/scDblFinder are scRNA-seq DROPLET methods (they simulate artificial doublets) - limited transfer, because cytometry has direct physical doublet signals.

FSC-A vs FSC-H Singlet Gating (flow/spectral)

Goal: Keep events on the singlet diagonal.

Approach: A polygon along the A=H diagonal (preferred over a rectangle, which keeps off-diagonal doublets); visualize with the gate overlaid.

library(flowCore); library(ggcyto)

# matrix dimnames preserve 'FSC-A'/'FSC-H'; data.frame() would mangle them to FSC.A
singlet <- polygonGate(filterId = 'singlets', .gate = matrix(
  c(20000, 10000, 250000, 200000, 250000, 260000, 20000, 40000), ncol = 2, byrow = TRUE,
  dimnames = list(NULL, c('FSC-A', 'FSC-H'))))
singlets <- Subset(fs, singlet)
autoplot(fs[[1]], 'FSC-A', 'FSC-H') + ggcyto::geom_gate(singlet)

CyTOF Doublet Removal

Goal: Keep intercalator-positive single ion clouds.

Approach: Gate DNA intercalator (nucleated, ~2N) and Event_length/Gaussian residual; CATALYST exposes these as channels in the SCE.

library(CATALYST)
# prepData moves Time/Event_length to int_colData by default - keep them in the assay with FACS=TRUE
sce <- prepData(fs, panel, md, transform = TRUE, cofactor = 5, FACS = TRUE)
e <- assay(sce, 'exprs')

dna <- e['DNA1', ]                                   # intercalator-positive = nucleated single cells
keep <- dna > quantile(dna, 0.05) & dna < quantile(dna, 0.95)
if ('Event_length' %in% rownames(sce))               # retained by FACS=TRUE (now on the arcsinh scale)
  keep <- keep & e['Event_length', ] <= quantile(e['Event_length', ], 0.99)   # quantile-relative, so scale is fine
sce_singlets <- sce[, keep]

Per-Method Failure Modes

1D area gate leaves doublets

Trigger: gating only FSC-A. Mechanism: doublets overlap singlets in area. Symptom: double-positive clusters persist. Fix: gate the FSC-A vs FSC-H diagonal (+ Width).

Heterotypic conjugate survives scatter gating

Trigger: a surprising double-positive between two single-positive clusters. Mechanism: T:monocyte conjugate is scatter-normal, lineage markers comparable to singlets. Symptom: "novel" DP population with an elevated shared marker (e.g. CD45). Fix: treat as suspected doublet; check the shared-marker signal; confirm/resolve by imaging flow (bright-field aspect ratio) when load-bearing.

CyTOF "doublet gate" using scatter

Trigger: porting flow logic to CyTOF. Mechanism: no FSC/SSC exists. Symptom: no scatter channels. Fix: use DNA + Gaussian/Event_length.

Quantitative Thresholds

Threshold Source Rationale
expected doublet rate ~1-5% (PBMC), higher in tissue community flag samples far above as prep issues - not a removal cutoff
Gaussian + DNA gating improves CV (3.45 -> ~2.04) Bagwell 2020 Cytometry A 97:184 combined DNA + Gaussian over baseline (Gaussian alone ~2.41)

Note: a fixed "95th-percentile residual" cutoff is arbitrary; prefer a visual diagonal gate or the instrument's Gaussian parameters over an unjustified quantile.

Common Errors

Error / symptom Cause Solution
double-positive cluster that "shouldn't" exist residual heterotypic doublets check for an elevated shared marker (CD45); confirm by imaging flow
no FSC/SSC channels (CyTOF) mass data has no scatter use DNA/Gaussian/Event_length
over-removal of large cells rectangle gate clips real large singlets use a diagonal polygon, not a box

References

  • Stadinski 2020 Cytometry A 97(11):1102-1104 — heterotypic doublets survive scatter gating.
  • Bagwell 2020 Cytometry A 97(2):184-198 — automated CyTOF cleanup via Gaussian/Event_length.
  • Finck 2013 Cytometry A 83(5):483-494 — CyTOF DNA/event parameters in normalization context.

Related Skills

Workflow order (CyTOF): EQ-bead drift normalization (raw, FIRST) -> cytometry-qc -> doublet-detection -> clustering -> CytoNorm cross-batch (LAST)

  • cytometry-qc - Run first: flow-rate/signal/margin cleaning
  • bead-normalization - CyTOF drift correction after doublet removal
  • fcs-handling - Load FCS files
  • gating-analysis - Where singlet discrimination sits in the hierarchy
  • clustering-phenotyping - Downstream analysis after doublet removal
  • single-cell/doublet-detection - Droplet scRNA-seq doublet methods (different principle)