smithery/gptomics

bio-flow-cytometry-compensation-transformation

Corrects fluorophore spillover (conventional compensation) or spectral overlap (spectral unmixing) and applies variance-stabilizing transforms (logicle/biexponential, arcsinh, log) for flow and mass cytometry. Covers spillover-matrix estimation from single-stain controls, AutoSpill, the spillover spreading matrix and why panel design (not compensation) bounds resolution, compensate-then-transform ordering, and arcsinh cofactor choice (5 for CyTOF, ~150 for fluorescence, per-channel via flowVS).…

Installation

$ npx skills add smithery/gptomics --skill bio-flow-cytometry-compensation-transformation

Summary

  • Corrects fluorophore spillover (conventional compensation) or spectral overlap (spectral unmixing) and applies variance-stabilizing transforms (logicle/biexponential, arcsinh, log) for flow and mass cytometry.
  • Covers spillover-matrix estimation from single-stain controls, AutoSpill, the spillover spreading matrix and why panel design (not compensation) bounds resolution, compensate-then-transform ordering, and arcsinh cofactor choice (5 for CyTOF, ~150 for fluorescence, per-channel via flowVS).
  • Use when correcting spectral overlap, preparing data for gating/clustering, choosing logicle vs arcsinh, deciding a cofactor, or distinguishing compensation from spectral unmixing.

Similar popular skills

Related neighbors and high-traction skills in the same topics — useful to compare before installing.

Also in this package

Other skills from smithery/gptomics · top by installs.

npx skills add smithery/gptomics

Browse all from smithery/gptomics

More details

Agent compatibility

Declared targets from SKILL.md / docs. Unmarked agents are not listed — the skill may still install via the CLI.

Claude Code Not declared
Cursor Not declared
Codex Not declared
GitHub Copilot Not declared
Windsurf Not declared
Gemini CLI Not declared
Cline Not declared
OpenCode Not declared

Package contents

Files included with this skill beyond the listing page.

  • skill md SKILL.md 11,281 B
  • docs SUMMARY.md 304 B

History

  1. First recorded snapshot · 0 installs

SKILL.md

Version Compatibility

Reference examples tested with: flowCore 2.14+, flowStats 4.14+, flowWorkspace 4.14+, CATALYST 1.26+.

Before using code patterns, verify installed versions match. If versions differ:

  • R: packageVersion('<pkg>') then ?function_name to verify parameters

Notes that bite: estimateLogicle() lives in flowWorkspace (not flowCore). flowCore::spillover() on a flowFrame returns a LIST of keyword matrices (index [[1]]); flowStats::spillover() on single-stain controls returns the matrix DIRECTLY (not a list) - do not index it with $.

If code throws an error, introspect the installed package and adapt rather than retrying.

Compensation and Transformation

"Compensate and transform my cytometry data" -> Remove spillover (matrix subtraction, conventional) or unmix the full spectrum (least squares, spectral), then apply a transform so populations separate.

  • R (conventional): flowCore::compensate() then flowWorkspace::estimateLogicle() + flowCore::transform()
  • R (CyTOF/mass): CATALYST::prepData(..., transform=TRUE, cofactor=5) (arcsinh)
  • R (spectral): linear UNMIXING, not compensation - see the taxonomy

The Single Most Important Modern Insight -- Compensation Corrects the Mean; It Cannot Remove Spreading Error

Conventional compensation inverts a square spillover matrix (peak-channel subtraction); spectral cytometry solves an OVERDETERMINED least-squares unmix over all detectors, with autofluorescence modeled as an extra "fluorophore." Both correct the population MEAN. Neither removes spreading error - the widening of a negative population in a spillover detector that arises from the Poisson counting statistics of the spilled-in photons (Roederer 2001 Cytometry 45:194; Nguyen 2013 Cytometry A 83:306). Compensation does not INTRODUCE spreading; it makes the pre-existing variance visible by re-centering means. The corollaries are load-bearing: (1) a smeared negative cannot be fixed by tuning the matrix - over-compensating to flatten it is data falsification; (2) spreading is fixed at PANEL DESIGN (the Spillover Spreading Matrix identifies which detector pairs to avoid for co-expressed/dim markers), never downstream; (3) calling spectral unmixing "compensation" is a category error - it is a different, overdetermined model.

Method Taxonomy

Method What it does When to use Fails when
Acquisition-recorded $SPILLOVER applies the cytometer-computed matrix trustworthy single-stain setup at acquisition controls were wrong/missing
Computed compensation (flowStats::spillover) estimates spillover from single-stain controls (medians) conventional flow, controls available poor/dim/contaminated controls
AutoSpill (Roca 2021 Nat Commun 12:2890) robust-regression matrix + iterative refinement; AF as endogenous dye high-parameter panels; messy controls reference implementation/setup unavailable
Spectral unmixing (OLS/WLS/Poisson) least-squares unmix full spectrum vs reference spectra + AF spectral cytometers (Aurora, ID7000) wrong/heterogeneous AF; collinear spectra
Logicle / biexponential display + analysis transform, handles negatives fluorescence flow wrong w clips the negative population
arcsinh variance-stabilizing transform CyTOF/mass; computational pipelines wrong cofactor compresses dim markers
log10 legacy rarely; strictly positive data any negative values after compensation

Decision Tree by Scenario

Scenario Recommended Why
Conventional flow, $SPILLOVER present apply recorded matrix -> estimateLogicle trust acquisition controls; logicle handles negatives
Conventional flow, no matrix compute via flowStats::spillover from single-stains (or AutoSpill) controls drive the matrix; AutoSpill for >12 colors
Spectral cytometer UNMIX (do NOT compensate), then arcsinh at ~150/per-channel (NOT 5) overdetermined system; spectral data is fluorescence-scale, not ion counts
CyTOF / mass arcsinh cofactor 5; spillover via CATALYST compCytof if needed metals barely spill (~1-4%), but oxide/impurity is real
Dim marker driving a borderline call test per-channel cofactor (flowVS) a fixed cofactor can manufacture/erase the population

Compensate-Then-Transform Ordering (load-bearing)

Compensation/unmixing is LINEAR and must run on untransformed data; applying it after a nonlinear transform is mathematically invalid. estimateLogicle() must run on ALREADY-COMPENSATED data so the w/a parameters reflect the post-compensation negative spread. Negative values after compensation are expected and meaningful - do NOT clip to zero before transforming (handling negatives is the entire reason logicle/arcsinh exist; log cannot).

Apply or Compute Compensation

Goal: Apply the recorded matrix, or estimate one from single-stain controls.

Approach: compensate() takes a compensation object built from the matrix; flowStats::spillover() estimates from single-stain controls and returns the matrix directly.

library(flowCore)

comp <- compensation(spillover(fcs)[[1]])      # flowCore: flowFrame -> list of keyword matrices
fcs_comp <- compensate(fcs, comp)

library(flowStats)
ctrls <- read.flowSet(list.files('controls', pattern = '\\.fcs$', full.names = TRUE))
comp_matrix <- spillover(ctrls, unstained = 'Unstained.fcs', fsc = 'FSC-A', ssc = 'SSC-A',
                         patt = '-A$', method = 'median')   # flowStats: returns the matrix directly

Logicle / Biexponential Transform (fluorescence)

Goal: Display and analyze compensated fluorescence with negatives handled honestly.

Approach: estimateLogicle() (flowWorkspace) derives w from the data's most-negative events; apply with transform().

library(flowWorkspace)

fluo <- colnames(fcs_comp)[grepl('-A$', colnames(fcs_comp)) & !grepl('FSC|SSC', colnames(fcs_comp))]
lgcl <- estimateLogicle(fcs_comp, channels = fluo)   # data-driven w; t=262144, m=4.5, a=0 defaults
fcs_t <- transform(fcs_comp, lgcl)

Arcsinh Transform (CyTOF cofactor 5; fluorescence/spectral ~150 or per-channel)

Goal: Variance-stabilize mass-cytometry counts (or any pipeline feeding clustering).

Approach: asinh(x/cofactor); flowCore's arcsinhTransform is asinh(a + b*x) + c, so set b=1/cofactor. CATALYST prepData defaults cofactor=5.

COFACTOR <- 5      # standard CyTOF cofactor, codified in the CATALYST workflow (Nowicka 2017); ~150 for fluorescence

asinhT <- arcsinhTransform(transformationId = 'asinh', a = 0, b = 1/COFACTOR, c = 0)
fcs_t  <- transform(fcs, transformList(marker_channels, asinhT))

# CATALYST path (CyTOF): cofactor=5 default; OVERRIDE for fluorescence/spectral
sce <- CATALYST::prepData(fs, panel, md, transform = TRUE, cofactor = COFACTOR)

Per-Method Failure Modes

Over-compensation (negative pull-down)

Trigger: matrix slope over-estimated from dim controls. Mechanism: subtraction overshoots. Symptom: negative population pulled below zero, "comma" shape. Fix: controls at least as bright as the sample; AutoSpill regression; never hand-tune to flatten spread.

Wrong logicle width clips negatives

Trigger: fixed w instead of estimateLogicle. Mechanism: linear region too narrow. Symptom: negative population piled on the axis. Fix: estimate w on compensated data.

Cofactor compresses a dim marker

Trigger: cofactor 5 on fluorescence (or 150 on CyTOF). Mechanism: linear region mismatched to the noise band. Symptom: dim-positive collapses into the negative; clusters don't reproduce. Fix: 5 for CyTOF, ~150 for fluorescence; per-channel via flowVS::estParamFlowVS.

Compensating spectral data

Trigger: treating Aurora data as conventional. Mechanism: subtraction is the wrong model for an overdetermined system. Symptom: residual spread, false positives. Fix: unmix against single-stain reference spectra + unstained AF.

Quantitative Thresholds

Threshold Source Rationale
arcsinh cofactor = 5 (mass) Nowicka 2017 F1000Res 6:748 (CATALYST workflow) matches CyTOF ion-count near-zero noise band
arcsinh cofactor ~150 (fluorescence) community/CATALYST convention (not a derived optimum) PMT photon scale is far larger; per-channel flowVS supersedes
comp control >= sample brightness Roederer 2001 Cytometry 45:194 slope estimated over the widest lever arm; extrapolation amplifies error
spreading is intensity-dependent (~sqrt of signal) Nguyen 2013 Cytometry A 83:306 SSM is normalized to be gain-independent for panel design

Common Errors

Error / symptom Cause Solution
compensate() channel mismatch matrix colnames != FCS channels align names before compensate
all-negative after transform transform applied before/without compensation compensate on linear data first
estimateLogicle not found called from flowCore it lives in flowWorkspace
arcsinhTransform ignores "cofactor" param is b, not cofactor set b = 1/cofactor

References

  • Roederer 2001 Cytometry 45(3):194-205 — spreading error / compensation artifacts.
  • Nguyen 2013 Cytometry A 83(3):306-315 — spillover spreading matrix; panel design.
  • Roca 2021 Nat Commun 12:2890 — AutoSpill robust-regression compensation.
  • Parks 2006 Cytometry A 69(6):541-551 — logicle display.
  • Moore & Parks 2012 Cytometry A 81(4):273-277 — logicle operational update.
  • Bendall 2011 Science 332(6030):687-696 — CyTOF mass cytometry; arcsinh-median analysis.
  • Nowicka 2017 F1000Research 6:748 — CATALYST workflow; codifies the cofactor-5 convention.
  • Azad 2016 BMC Bioinformatics 17:291 — flowVS per-channel cofactor.
  • Chevrier 2018 Cell Syst 6(5):612-620 — CyTOF spillover compensation (CATALYST).

Related Skills

  • fcs-handling - Load FCS and retrieve the spillover keyword first
  • gating-analysis - Gate on the transformed, compensated scale
  • clustering-phenotyping - Cluster compensated, transformed data
  • cytometry-qc - QC before and after preprocessing
  • imaging-mass-cytometry/data-preprocessing - Shared arcsinh/metal-channel conventions
  • spatial-transcriptomics/spatial-proteomics - Spectral/metal unmixing context